Персона: Артамонов, Алексей Сергеевич
Email Address
Birth Date
Научные группы
Организационные подразделения
Статус
Фамилия
Имя
Имя
Результаты поиска
Detectors of Radiation Based on Aluminum Nitride and Aluminum and Silicon Oxides
2022, Aluker, N. L., Artamonov, A. S., Артамонов, Алексей Сергеевич
Abstract: A study is performed of the optical and physical properties of oxide materials and aluminum nitride that allow targeted approaches to developing criteria for estimating the dosimetry potential of materials. It is proposed that mass-produced oxide thermoluminescent detectors and ceramic materials based on AlN and Al2O3 be used in the dosimetry of weakly penetrating radiation of high intensity. © 2022, Allerton Press, Inc.
Thermoluminescent Detectors of High-Density Ionizing Radiation
2021, Aluker, N. L., Herrmann, M., Artamonov, A. S., Артамонов, Алексей Сергеевич
© 2021, Pleiades Publishing, Ltd.Abstract: The study demonstrates use of TLD-K thermoluminescent detectors of ionizing radiation, which are made of a glass-based amorphous material, to measure high-density and high-intensity radiation, i.e., to doses of up to 1 kGy in the operating dosimetric peak at dose rates of up to 1011 Gy/s.
Thermoluminescence of Dense β-Ga2O3 Ceramics Synthesized by Plasma Gas-Thermal Spraying
2025, Aluker, N. L., Artamonov, A. S., Muslimov, A. E., Gadzhiev, M. Kh., Артамонов, Алексей Сергеевич
Thermoluminescent Dosimeters Based on Aluminum Oxide and Aluminum Nitride Ceramics
2021, Aluker, N. L., Gimadova, T. I., Zverev, A. S., Artamonov, A. S., Артамонов, Алексей Сергеевич
© 2021, Pleiades Publishing, Ltd.Abstract—: The luminescence characteristics of commercial ceramic substrates based on AlN and Al2O3 have been investigated. Based on the results, it is possible to determine the conditions under which these materials can be used in ionizing-radiation dosimetry. The TLD-K and TLD-500 thermoluminescent detectors are used for comparison.
Radiation Monitoring as a Measure to Improve the Safety of Coal Mining
2022, Aluker, N. L., Artamonov, A. S., Herrmann, M., Артамонов, Алексей Сергеевич
Response of Dosimetric Materials to Pico- and Nanosecond Laser Radiation at Comparable Light Flux Intensities
2025, Aduyev, B. P., Aluker, N. L., Artamonov, A. S., Nurmukhametov, D. R., Артамонов, Алексей Сергеевич
X-ray Based Electronic Components Authentication Methods to Counterfeit Detection
2021, Shirin, A. O., Taiibov, F. F., Simakhin, E. A., Kessarinskiy, L. N., Koval, K. A., Artamonov, A. S., Durakovskiy, A. P., Симахин, Егор Андреевич, Кессаринский, Леонид Николаевич, Коваль, Кирилл Александрович, Артамонов, Алексей Сергеевич, Дураковский, Анатолий Петрович
© 2021 IEEE.The problem of counterfeit products, electronic and electromechanical products is presented. One of the most effective non-destructive electronics analyses is x-ray checking, that is presented in this paper.
Diagnostics of Pulsed Laser Action on Wide-Gap Materials Using Thermoluminescent Dosimetry
2023, Aluker, N. L., Artamonov, A. S., Nurmukhametov, D. R., Aduev, B. P., Артамонов, Алексей Сергеевич
АНАЛИЗ ВОЗМОЖНОСТИ ПРИМЕНЕНИЯ СИСТЕМЫ РЕНТГЕНОВСКОГО КОНТРОЛЯ ДЛЯ ОЦЕНКИ МАССОВОЙ ТОЛЩИНЫ КОРПУСОВ ИНТЕГРАЛЬНЫХ СХЕМ
2024, Артамонов, А. С., Бойченко, Д. В., Каменева, А. С., Каменева, Анна Сергеевна, Бойченко, Дмитрий Владимирович, Артамонов, Алексей Сергеевич
В работе проводится анализ возможности применения типовой установки рентгеновского контроля для оценки массовой толщины корпусов интегральных схем. Проведение подобных оценок необходимо для корректного определения значений линейных потерь энергии ионов при проведении экспериментальных исследований на ускорителях ионов высоких энергий корпусированных изделий микроэлектроники. Представлены предварительные результаты, демонстрирующие такую возможность. Рассмотрены особенности конструкции и работы системы рентгеновского контроля и выявлено, что на результаты оценок оказывает сильное влияние нестабильность характеристик рентгеновской установки, расходимость рентгеновского излучения и точность позиционирования изделия. Обоснован метод оценки массовой толщины корпусов с использованием одновременного облучения клина из известного материала с исследуемым образцом. С целью уменьшения влияния размерных эффектов допускается при наличии такой возможности обрезка части корпуса.