Publication:
Photon counting mode for advanced real-time detection of bioaerosols

dc.contributor.authorTkachuk, A. P.
dc.contributor.authorVerdiev, B. I.
dc.contributor.authorAlatirev, A. G.
dc.contributor.authorAkmalov, A. E.
dc.contributor.authorChistyakov, A. A.
dc.contributor.authorKotkovskii, G. E.
dc.contributor.authorKuzishchin, Y. A.
dc.contributor.authorMartynov, I. L.
dc.contributor.authorOsipov, E. V.
dc.contributor.authorPashkevich, A. A.
dc.contributor.authorАкмалов, Артём Эдуардович
dc.contributor.authorЧистяков, Александр Александрович
dc.contributor.authorКотковский, Геннадий Евгеньевич
dc.contributor.authorКузищин, Юрий Александрович
dc.contributor.authorМартынов, Игорь Леонидович
dc.contributor.authorОсипов, Евгений Валерьевич
dc.contributor.authorПашкевич, Александра Андреевна
dc.date.accessioned2024-11-29T23:01:33Z
dc.date.available2024-11-29T23:01:33Z
dc.date.issued2021
dc.description.abstract© 2021 SPIECurrently, one of the most important application of flow cytometry is the real-time analysis of aerosols, in particular, to ensure biosafety. In most cases, such analysis is aimed at detecting fluorescent signals from aerosol particles corresponding to the light emission of tryptophan and nicotinamide adenine dinucleotide (NADH). Further development of the method is largely related to the improvement of the light detecting systems for recording and processing of fluorescence and scattered light signals. In this work, a comparative analysis of flow cytometers for bioaerosols detection based on photo-multiplier tubes (PMT) and avalanche photodiodes (APD) operating in analog and photon-counting modes was carried out. The limit of detection (LOD) of bioaerosols, response time and ability to detect particles with low scattering and fluorescence cross section were calculated and examined. The calculations were carried out for the well-known optical scheme of fluorescence detection based on discrete photodetectors and dichroic mirrors combined with an air flow chamber equipped with elliptical and spherical mirrors. An ultraviolet light emission diode (LED) was used as a model source of exciting radiation. To estimate the optical properties of aerosol particles, experimental results obtained for a model bovine serum albumin bioaerosol and published data on various other bioaerosols were used. The calculation of the total number of fluorescent photons, emitted by particles of various sizes while passing the flow chamber was carried out. The obtained data were compared with parameters of photodetectors operating in analog and photon-counting modes. The critical particle size was determined for the effective registration in a photon-counting mode. Considering the size distribution of aerosol particles, it was concluded that application of the photon-counting mode will reduce the LOD of bioaerosols by more than an order of magnitude.
dc.identifier.citationPhoton counting mode for advanced real-time detection of bioaerosols / Tkachuk, A.P. [et al.] // Proceedings of SPIE - The International Society for Optical Engineering. - 2021. - 11869. - 10.1117/12.2600476
dc.identifier.doi10.1117/12.2600476
dc.identifier.urihttps://www.doi.org/10.1117/12.2600476
dc.identifier.urihttps://www.scopus.com/record/display.uri?eid=2-s2.0-85118890916&origin=resultslist
dc.identifier.urihttps://openrepository.mephi.ru/handle/123456789/24955
dc.relation.ispartofProceedings of SPIE - The International Society for Optical Engineering
dc.titlePhoton counting mode for advanced real-time detection of bioaerosols
dc.typeConference Paper
dspace.entity.typePublication
oaire.citation.volume11869
relation.isAuthorOfPublicationdec281e4-1bc3-4915-a9d3-29c3921bc4c4
relation.isAuthorOfPublication2bcf3ea6-b96d-4ef0-8d9a-f78f774cec84
relation.isAuthorOfPublication650702d9-1bf6-4c3c-b1c7-feca4e50fea2
relation.isAuthorOfPublication2d7bebdf-dd59-4c4d-966e-ff569e10f686
relation.isAuthorOfPublication838e2b54-3381-429a-ab1d-1af04f9d7536
relation.isAuthorOfPublication5ca2edf9-e377-4645-bc24-44cc9a7221e0
relation.isAuthorOfPublication966ab3c4-b2b1-4037-99ec-eced44a516ef
relation.isAuthorOfPublication.latestForDiscoverydec281e4-1bc3-4915-a9d3-29c3921bc4c4
relation.isOrgUnitOfPublication06e1796d-4f55-4057-8d7e-bb2f3b5676f5
relation.isOrgUnitOfPublication.latestForDiscovery06e1796d-4f55-4057-8d7e-bb2f3b5676f5
Файлы
Коллекции