Publication: Non-invasive high-contrast infrared imaging of blood vessels in biological tissues by the backscattered laser radiation method
dc.contributor.author | Grachev, P. | |
dc.contributor.author | Moskalev, A. | |
dc.contributor.author | Efendiev, K. | |
dc.contributor.author | Loschenov, V. | |
dc.contributor.author | Эфендиев, Канамат Темботович | |
dc.contributor.author | Лощенов, Виктор Борисович | |
dc.date.accessioned | 2024-11-27T09:15:00Z | |
dc.date.available | 2024-11-27T09:15:00Z | |
dc.date.issued | 2020 | |
dc.description.abstract | © 2020 Elsevier B.V.The work is devoted to non-invasive visualization of human blood vessels in the near-infrared range by backscattered laser radiation. This article presents an effective approach to infrared imaging using the backscattered laser method. The most optimal range of wavelengths (760–800 nm) for infrared imaging of blood vessels has been determined. The results of the simulation of laser radiation in human skin models by the Monte-Carlo method are presented. A system has been developed for conducting non-invasive infrared imaging of the bloodstream. | |
dc.identifier.citation | Non-invasive high-contrast infrared imaging of blood vessels in biological tissues by the backscattered laser radiation method / Grachev, P. [et al.] // Infrared Physics and Technology. - 2020. - 111. - 10.1016/j.infrared.2020.103562 | |
dc.identifier.doi | 10.1016/j.infrared.2020.103562 | |
dc.identifier.uri | https://www.doi.org/10.1016/j.infrared.2020.103562 | |
dc.identifier.uri | https://www.scopus.com/record/display.uri?eid=2-s2.0-85094920150&origin=resultslist | |
dc.identifier.uri | http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=Alerting&SrcApp=Alerting&DestApp=WOS_CPL&DestLinkType=FullRecord&UT=WOS:000599838900003 | |
dc.identifier.uri | https://openrepository.mephi.ru/handle/123456789/22522 | |
dc.relation.ispartof | Infrared Physics and Technology | |
dc.title | Non-invasive high-contrast infrared imaging of blood vessels in biological tissues by the backscattered laser radiation method | |
dc.type | Article | |
dspace.entity.type | Publication | |
oaire.citation.volume | 111 | |
relation.isAuthorOfPublication | 7f769f9f-8af2-48fd-bdad-b0e02337ad6c | |
relation.isAuthorOfPublication | 371640a5-5007-444c-a657-ccfac33ccebd | |
relation.isAuthorOfPublication.latestForDiscovery | 7f769f9f-8af2-48fd-bdad-b0e02337ad6c | |
relation.isOrgUnitOfPublication | c8407a6f-7272-450d-8d99-032352c76b55 | |
relation.isOrgUnitOfPublication.latestForDiscovery | c8407a6f-7272-450d-8d99-032352c76b55 |