Publication:
Influence of Type and Configuration of the Atom Probe Tomography Setup with Laser Evaporation on the Data Reconstruction Accuracy

dc.contributor.authorButov, N. A.
dc.contributor.authorRudskoy, B. V.
dc.contributor.authorAkopyan, T. K.
dc.contributor.authorLukyanchuk, A. A.
dc.contributor.authorRaznitsyn, O. A.
dc.contributor.authorShutov, A. S.
dc.contributor.authorAleev, A. A.
dc.contributor.authorKlauz, A. V.
dc.contributor.authorRogozhkin, S. V.
dc.contributor.authorЛукьянчук, Антон Алексеевич
dc.contributor.authorРазницын, Олег Анатольевич
dc.contributor.authorШутов, Антон Сергеевич
dc.contributor.authorАлеев, Андрей Аскольдович
dc.contributor.authorКлауз, Артём Вадимович
dc.contributor.authorРогожкин, Сергей Васильевич
dc.date.accessioned2024-11-30T02:52:06Z
dc.date.available2024-11-30T02:52:06Z
dc.date.issued2021
dc.description.abstract© 2021, Pleiades Publishing, Ltd.Abstract: Atom probe tomography (APT) is a tool for detailed chemical composition analysis of advanced structural material nanostructure. The use of different Atomic Probe Tomography (APT) devices requires a certification of these setups prior to conducting research. In this paper a method of comparing APT setups in order to evaluate the influence of the overall system configuration on the accuracy of obtained data is proposed. The collected data comparison is presented for the aluminum alloy Al–3.3Cu–2.5Mn–0.5Zr and structural steel 16Kh12МVSFBR gathered on the APPLE-3D (“PAZL-3D”) setup and on the new ATLAS (“ATLAZ”) unit, created through upgrading the ECOTAP. Comparison of the results confirms the feasibility of carrying out research of the same material on similar setups without significant distortion of the data under its analysis and interpretation.
dc.format.extentС. 2004-2009
dc.identifier.citationInfluence of Type and Configuration of the Atom Probe Tomography Setup with Laser Evaporation on the Data Reconstruction Accuracy / Butov, N.A. [et al.] // Physics of Atomic Nuclei. - 2021. - 84. - № 12. - P. 2004-2009. - 10.1134/S106377882112005X
dc.identifier.doi10.1134/S106377882112005X
dc.identifier.urihttps://www.doi.org/10.1134/S106377882112005X
dc.identifier.urihttps://www.scopus.com/record/display.uri?eid=2-s2.0-85126002461&origin=resultslist
dc.identifier.urihttp://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=Alerting&SrcApp=Alerting&DestApp=WOS_CPL&DestLinkType=FullRecord&UT=WOS:000761332100014
dc.identifier.urihttps://openrepository.mephi.ru/handle/123456789/25315
dc.relation.ispartofPhysics of Atomic Nuclei
dc.titleInfluence of Type and Configuration of the Atom Probe Tomography Setup with Laser Evaporation on the Data Reconstruction Accuracy
dc.typeArticle
dspace.entity.typePublication
oaire.citation.issue12
oaire.citation.volume84
relation.isAuthorOfPublication4fce4a85-bd46-4ce8-a47c-4fad7b6144d5
relation.isAuthorOfPublication8ea6185a-ac43-49b9-96d1-537ec4e991b1
relation.isAuthorOfPublicationfb8b42df-a428-4875-a13e-62843176de32
relation.isAuthorOfPublicationf386e480-148b-422a-b578-8e150656c9ec
relation.isAuthorOfPublication246d9e45-3ed8-44ec-8b5f-8ed0ef1906b0
relation.isAuthorOfPublication339ead5b-5bac-40ad-9ff1-54311a771be1
relation.isAuthorOfPublication.latestForDiscovery4fce4a85-bd46-4ce8-a47c-4fad7b6144d5
relation.isOrgUnitOfPublicationba0b4738-e6bd-4285-bda5-16ab2240dbd1
relation.isOrgUnitOfPublication.latestForDiscoveryba0b4738-e6bd-4285-bda5-16ab2240dbd1
Файлы
Коллекции