© 27th Russian Particle Accelerator Conference, RuPAC 2021. All rights reserved.Design of the cryomodule prototype for testing low-beta 325 MHz half-wave cavities is currently in the process at INP BSU. The cryomodule allows performing intermediate vacuum-, temperature-, and rf-tests during the fabrication of half-wave resonators. The irst experimental results of cryomodule cooling down to liquid nitrogen temperatures are presented and discussed. The pressure and temperature control allows us to estimate the main cooling/heating characteristics of the cryostat at diferent operation stages. The presented test cryomodule will be used for further development and production of superconductive niobium cavities for the Nuclotron-based Ion Collider fAcility (NICA) injector.
Описание
Ключевые слова
Цитирование
DESIGN AND CHARACTERISTICS OF CRYOSTAT FOR TESTING OF LOW-BETA 325 MHZ HALF-WAVE RESONATORS / Bychanok, D. [et al.] // CERN-Proceedings. - 2021. - 2021-September. - P. 165-167. - 10.18429/JACoW-RuPAC2021-MOPSA16