Publication:
Precision Spectrometric Search Dosimeter-Radiometer Based on a Matrix SiPM, Designed to Restore the Geometry of Ionizing Radiation Sources

dc.contributor.authorKondrateva, A.
dc.contributor.authorFlorentsev, V.
dc.contributor.authorBaryshev, G.
dc.contributor.authorBerestov, A.
dc.contributor.authorBiryukov, A.
dc.contributor.authorБарышев, Геннадий Константинович
dc.contributor.authorБерестов, Александр Васильевич
dc.contributor.authorБирюков, Александр Павлович
dc.date.accessioned2024-11-29T10:38:08Z
dc.date.available2024-11-29T10:38:08Z
dc.date.issued2021
dc.description.abstract© 2021, Springer Nature Switzerland AG.The improvement of spectrometric devices and methods makes it possible to create a fundamentally new device that can distinguish not only the energy characteristics and activity of ionizing radiation sources. Today, devices are also expected to be able to quickly determine the geometry of the source, and not only from a set of standard ones. The method discussed in the article describes how the use of SiPM matrices allows detecting angular characteristics of the direction of gamma radiation incidence on the detector, allowing you to determine the position and types of sources. The detector created by this method has high sensitivity and resolution. These properties make it possible to use it in nuclear medicine to study the distribution of isotopes in the human body, in crystallography, archaeology, radiation safety systems, etc.
dc.format.extentС. 113-120
dc.identifier.citationPrecision Spectrometric Search Dosimeter-Radiometer Based on a Matrix SiPM, Designed to Restore the Geometry of Ionizing Radiation Sources / Kondrateva, A. [et al.] // Springer Proceedings in Physics. - 2021. - 255. - P. 113-120. - 10.1007/978-3-030-58868-7_13
dc.identifier.doi10.1007/978-3-030-58868-7_13
dc.identifier.urihttps://www.doi.org/10.1007/978-3-030-58868-7_13
dc.identifier.urihttps://www.scopus.com/record/display.uri?eid=2-s2.0-85097643636&origin=resultslist
dc.identifier.urihttps://openrepository.mephi.ru/handle/123456789/23497
dc.relation.ispartofSpringer Proceedings in Physics
dc.titlePrecision Spectrometric Search Dosimeter-Radiometer Based on a Matrix SiPM, Designed to Restore the Geometry of Ionizing Radiation Sources
dc.typeConference Paper
dspace.entity.typePublication
oaire.citation.volume255
relation.isAuthorOfPublication1ec388ac-3d83-48de-bca7-cc284f7f4276
relation.isAuthorOfPublication4156a19c-7e29-46fe-b5bf-5e5c34c7143a
relation.isAuthorOfPublicationb73d31e0-c4f6-4875-a605-e9e0c561a9c4
relation.isAuthorOfPublication.latestForDiscovery1ec388ac-3d83-48de-bca7-cc284f7f4276
relation.isOrgUnitOfPublication74cb61de-96b0-45f9-956d-515149fba360
relation.isOrgUnitOfPublication543ffddb-d115-4466-be75-83b0f2c5a473
relation.isOrgUnitOfPublication.latestForDiscovery74cb61de-96b0-45f9-956d-515149fba360
Файлы
Коллекции