Publication: Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50
| dc.contributor.author | Agnes, P. | |
| dc.contributor.author | Albuquerque, I. F. M. | |
| dc.contributor.author | Alexander, T. | |
| dc.contributor.author | Alton, A. K. | |
| dc.contributor.author | Grobov, A. V. | |
| dc.contributor.author | Machulin, I. N. | |
| dc.contributor.author | Nozdrina, A. O. | |
| dc.contributor.author | Skorokhvatov, M. D. | |
| dc.contributor.author | Мачулин, Игорь Николаевич | |
| dc.contributor.author | Скорохватов, Михаил Дмитриевич | |
| dc.date.accessioned | 2024-11-29T21:29:07Z | |
| dc.date.available | 2024-11-29T21:29:07Z | |
| dc.date.issued | 2021 | |
| dc.description.abstract | © 2021 American Physical Society. DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV/c2 mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows us to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to ∼180 eVer, exploiting Ar37 and Ar39 decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Moreover, we present a model-dependent determination of the ionization response to nuclear recoils down to ∼500 eVnr, the lowest ever achieved in liquid argon, using in situ neutron calibration sources and external datasets from neutron beam experiments. | |
| dc.identifier.citation | Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50 / Agnes, P. [et al.] // Physical Review D. - 2021. - 104. - № 8. - 10.1103/PhysRevD.104.082005 | |
| dc.identifier.doi | 10.1103/PhysRevD.104.082005 | |
| dc.identifier.uri | https://www.doi.org/10.1103/PhysRevD.104.082005 | |
| dc.identifier.uri | https://www.scopus.com/record/display.uri?eid=2-s2.0-85117217452&origin=resultslist | |
| dc.identifier.uri | https://openrepository.mephi.ru/handle/123456789/24808 | |
| dc.relation.ispartof | Physical Review D | |
| dc.title | Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50 | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| oaire.citation.issue | 8 | |
| oaire.citation.volume | 104 | |
| relation.isAuthorOfPublication | 8818c043-2e70-479e-a5f8-d0d8a1f8c4f6 | |
| relation.isAuthorOfPublication | 5c5e7ef1-245d-4eec-b630-2e54eb740f1f | |
| relation.isAuthorOfPublication.latestForDiscovery | 8818c043-2e70-479e-a5f8-d0d8a1f8c4f6 | |
| relation.isOrgUnitOfPublication | ba0b4738-e6bd-4285-bda5-16ab2240dbd1 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | ba0b4738-e6bd-4285-bda5-16ab2240dbd1 |