Publication:
Effects of evaluated nuclear data libraries on the calculation results for fuel burnup with minor actinides in a VVER reactor

creativeworkseries.issn2452-3038
dc.contributor.authorKarpovich, G. W.
dc.contributor.authorKazansky, Yu. A.
dc.contributor.authorBakhantsov, K. A.
dc.contributor.authorIsanov, K. A.
dc.contributor.authorKushnir, N. O.
dc.date.accessioned2023-11-01T07:08:46Z
dc.date.available2023-11-01T07:08:46Z
dc.date.issued2023
dc.description.abstractThe paper deals with assessing the effects of the ENDF/B-VI.8, ENDF/B-VII.0, JEFF 3.1 and JEFF 3.1.1 nuclear data libraries on the results of calculating a number of functionals for a system based on a VVER reactor with fuel with a large fraction of minor actinides (up to 10%). Key estimates have been obtained for the errors introduced by libraries in calculations of systems with minor actinides (MA) based on a VVER-1200 reactor: – for reactivity, σρ = 0.3 βeff; – for isotopic compositions with minor actinides, ≤ 5% (the error for each particular isotope is different); – for the total mass of accumulated MAs, εm = 0.8%. Conclusions have been made with respect to the need for the further refinement of the library MA data proceeding from the nature of the calculation tasks that dictate the requirements for the accuracy of nuclear constants. It has been shown that systems based on VVER-1000/1200/1300 reactors with MAs need to be calculated using several libraries of evaluated nuclear data created at different organizations and based on the largest possible number of non-recurrent sets of experimental data.
dc.identifier.citationKarpovich GW, Kazansky YuA, Bakhantsov KA, Isanov KA, Kushnir NO (2023) Effects of evaluated nuclear data libraries on the calculation results for fuel burnup with minor actinides in a VVER reactor. Nuclear Energy and Technology 9(3): 163-169. https://doi.org/10.3897/nucet.9.112327
dc.identifier.doi10.3897/nucet.9.112327
dc.identifier.issn2452-3038
dc.identifier.urihttps://openrepository.mephi.ru/handle/123456789/1135
dc.identifier.urihttps://doi.org/10.3897/nucet.9.112327
dc.relation.ispartofNuclear Energy and Technology
dc.subjectcalculation accuracy
dc.subjectminor actinides
dc.subjectevaluated nuclear data libraries
dc.subjectnuclear fuel
dc.subjectburnup
dc.subjectVVER reactor
dc.subjectMonte Carlo method
dc.titleEffects of evaluated nuclear data libraries on the calculation results for fuel burnup with minor actinides in a VVER reactor
dc.typejournal-article
dspace.entity.typePublication
oaire.citation.issue3
oaire.citation.volume9
relation.isJournalIssueOfPublication672ef96d-87a1-41af-ae73-bd0fe6346122
relation.isJournalIssueOfPublication.latestForDiscovery672ef96d-87a1-41af-ae73-bd0fe6346122
relation.isJournalOfPublicatione11ecc6c-1851-485a-af73-18119b4fce7f
relation.isOrgUnitOfPublicationba0b4738-e6bd-4285-bda5-16ab2240dbd1
relation.isOrgUnitOfPublication.latestForDiscoveryba0b4738-e6bd-4285-bda5-16ab2240dbd1
Файлы
Original bundle
Теперь показываю 1 - 1 из 1
Загружается...
Уменьшенное изображение
Name:
NUCET_article_112327_en_1.pdf
Size:
639.14 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Теперь показываю 1 - 1 из 1
Загружается...
Уменьшенное изображение
Name:
license.txt
Size:
3.45 KB
Format:
Item-specific license agreed to upon submission
Description:
Коллекции