Publication:
Elaboration of 3-frame complex interferometry for optimization studies of capacitor-coil optical magnetic field generators

dc.contributor.authorPisarczyk, T.
dc.contributor.authorSantos, J. J.
dc.contributor.authorDudzak, R.
dc.contributor.authorZaras-Szydowska, A.
dc.contributor.authorGus'kov, S. Y.
dc.contributor.authorKorneev, P.
dc.contributor.authorKochetkov, I.
dc.contributor.authorКорнеев, Филипп Александрович
dc.contributor.authorКочетков, Юрий Владимирович
dc.date.accessioned2024-11-21T17:38:25Z
dc.date.available2024-11-21T17:38:25Z
dc.date.issued2019
dc.description.abstractRecently developed three-frame complex-interferometry system driven by a Ti:Sa laser with 40 fs pulse has been installed at the PALS (Prague Asterix Laser System) laser facility. This unique diagnostic allows for the first time to perform simultaneous measurements of B-field in the coil region of the capacitor-coil targets (CCT) and the self-generated B-field (SMF) of the diode plasma in between the CCT-plates. CCT were irradiated by the PALS iodine laser (lambda = 1315 nm) with energy in the range 250-500 J and pulse duration of 350 ps at full width at half maximum. The operation of this diagnostic system and methodologies for quantitative data analysis are presented in this study, including: (i) obtaining information about the induction of the magnetic field in the CCT coil based on measurements of the Faraday effect in the TGG (Terbium Gallium Garnet) paramagnetic crystal at the coil vicinity and (ii) determining magnetic field and current density distributions in the capacitor region of the CCT by analysis of the complex interferograms. The preliminary measurements confirmed the high potential of the reported setup for optimization studies of CCT targets.
dc.identifier.citationElaboration of 3-frame complex interferometry for optimization studies of capacitor-coil optical magnetic field generators / Pisarczyk, T [et al.] // Journal of Instrumentation. - 2019. - 14. - 10.1088/1748-0221/14/11/C11024
dc.identifier.doi10.1088/1748-0221/14/11/C11024
dc.identifier.urihttps://www.doi.org/10.1088/1748-0221/14/11/C11024
dc.identifier.urihttps://www.scopus.com/record/display.uri?eid=2-s2.0-85081960405&origin=resultslist
dc.identifier.urihttp://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=Alerting&SrcApp=Alerting&DestApp=WOS_CPL&DestLinkType=FullRecord&UT=WOS:000507588300024
dc.identifier.urihttps://openrepository.mephi.ru/handle/123456789/19377
dc.relation.ispartofJournal of Instrumentation
dc.titleElaboration of 3-frame complex interferometry for optimization studies of capacitor-coil optical magnetic field generators
dc.typeConference Paper
dspace.entity.typePublication
oaire.citation.volume14
relation.isAuthorOfPublicationc1864031-d8d5-494b-ab4c-9e548b0ef172
relation.isAuthorOfPublication78270804-59b8-4aa6-9232-4876cdddbda9
relation.isAuthorOfPublication.latestForDiscoveryc1864031-d8d5-494b-ab4c-9e548b0ef172
relation.isOrgUnitOfPublicationc8407a6f-7272-450d-8d99-032352c76b55
relation.isOrgUnitOfPublicationdcdb137c-0528-46a5-841b-780227a67cce
relation.isOrgUnitOfPublication.latestForDiscoveryc8407a6f-7272-450d-8d99-032352c76b55
Файлы
Коллекции