dc.description.abstract© 2019 Published under licence by IOP Publishing Ltd.The article is devoted to the analysis of the possibilities of improving the accuracy of the analysis of low-contrast images in the computer microscopy systems. The image distortion factors are considered in the system of computer microscopy with a camera based on a light-sensitive electronic matrix. The level of distortion of the image sensor signal in the computer microscopy system was estimated on the results of the experiment. The model of correction of distortions of the image sensor signal is offered. The application of the proposed model will provide an increase in the accuracy of automated analysis of microscopic images of low-contrast objects in the computer microscopy systems.
dc.identifier.citationModel of image sensor signal correction in the computer microscopy system / Nikitaev, V.G. [et al.] // Journal of Physics: Conference Series. - 2019. - 1205. - № 1. - 10.1088/1742-6596/1205/1/012041
dc.identifier.doi10.1088/1742-6596/1205/1/012041
dc.identifier.urihttps://www.doi.org/10.1088/1742-6596/1205/1/012041
dc.identifier.urihttps://www.scopus.com/record/display.uri?eid=2-s2.0-85066335897&origin=resultslist
dc.identifier.urihttp://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=Alerting&SrcApp=Alerting&DestApp=WOS_CPL&DestLinkType=FullRecord&UT=WOS:000481606200041
dc.identifier.urihttps://openrepository.mephi.ru/handle/123456789/18142
dc.relation.ispartofJournal of Physics: Conference Series
dc.titleModel of image sensor signal correction in the computer microscopy system
dc.typeConference Paper
dspace.entity.typePublication
oaire.citation.issue1
oaire.citation.volume1205
relation.isAuthorOfPublication53f47b8c-f04b-4530-80a6-bfb5955f4218
relation.isAuthorOfPublication7c96826d-cfbd-460d-a334-0e2fd80f79e8
relation.isAuthorOfPublicatione5947ca2-776c-4383-9de0-bcbbd8d52d19
relation.isAuthorOfPublication5a7629b7-cda6-436f-8bb3-c84a0e8c5613
relation.isAuthorOfPublicationdaa99507-9293-4113-a428-5f03879a5bc6
relation.isAuthorOfPublication.latestForDiscovery53f47b8c-f04b-4530-80a6-bfb5955f4218
relation.isOrgUnitOfPublicationc8407a6f-7272-450d-8d99-032352c76b55
relation.isOrgUnitOfPublication543ffddb-d115-4466-be75-83b0f2c5a473
relation.isOrgUnitOfPublicationdcdb137c-0528-46a5-841b-780227a67cce
relation.isOrgUnitOfPublication.latestForDiscoveryc8407a6f-7272-450d-8d99-032352c76b55
Файлы
Original bundle
Теперь показываю 1 - 1 из 1
Загружается...
Уменьшенное изображение
Name:
W2943930886.pdf
Size:
461.49 KB
Format:
Adobe Portable Document Format
Description:
Коллекции