Publication:
Flicker-Noise Spectroscopy analysis of magnetoencephalogram signals in diagnosis and treatment of photosensitive epilepsy

dc.contributor.authorDemin, S. A.
dc.contributor.authorYunusov, V. A.
dc.contributor.authorTimashev, S. F.
dc.contributor.authorТимашев, Сергей Федорович
dc.date.accessioned2024-12-25T14:31:11Z
dc.date.available2024-12-25T14:31:11Z
dc.date.issued2022
dc.description.abstract© 2022 SPIE.Our study demonstrates the potential of Flicker-Noise Spectroscopy analysis of neuromagnetic brain responses (magnetoencephalograms) in possible diagnosis and estimating the effectiveness of treatment of photosensitive epilepsy. The tendency of the organism to restore the synchronization to its normal levels is considered the cornerstone of the analysis. A two-parameter Flicker-Noise Spectroscopy cross-correlation function is applied to show that the breakdown of frequency-phase synchronization in the magnetoencephalograms of the patient can be associated with two distinct mechanisms: high-frequency resonances (50-100 Hz) at specific brain areas and changes in high-frequency stochastic components for other brain areas. Our analysis also reveals a certain disruption of regular behavior and occurrence of asymmetry in three-dimensional plots of the cross-correlation function for some healthy controls, suggesting that these individuals may be susceptible to photosensitive epilepsy. We believe that a similar cross-correlation analysis based on appropriate biomedical signals may be used to assess the effectiveness of medical treatment for other diseases and conditions.
dc.identifier.citationDemin, S. A. Flicker-Noise Spectroscopy analysis of magnetoencephalogram signals in diagnosis and treatment of photosensitive epilepsy / Demin, S.A., Yunusov, V.A., Timashev, S.F. // Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - 2022. - 12194. - 10.1117/12.2623095
dc.identifier.doi10.1117/12.2623095
dc.identifier.urihttps://www.doi.org/10.1117/12.2623095
dc.identifier.urihttps://www.scopus.com/record/display.uri?eid=2-s2.0-85132036668&origin=resultslist
dc.identifier.urihttps://openrepository.mephi.ru/handle/123456789/27998
dc.relation.ispartofProgress in Biomedical Optics and Imaging - Proceedings of SPIE
dc.titleFlicker-Noise Spectroscopy analysis of magnetoencephalogram signals in diagnosis and treatment of photosensitive epilepsy
dc.typeConference Paper
dspace.entity.typePublication
oaire.citation.volume12194
relation.isAuthorOfPublication335de349-29a3-4bc6-8b5d-f553a65beaf6
relation.isAuthorOfPublication.latestForDiscovery335de349-29a3-4bc6-8b5d-f553a65beaf6
relation.isOrgUnitOfPublication06e1796d-4f55-4057-8d7e-bb2f3b5676f5
relation.isOrgUnitOfPublication.latestForDiscovery06e1796d-4f55-4057-8d7e-bb2f3b5676f5
Файлы
Коллекции