Publication:
The Optimal Estimation of Single Event Effects Sensitivity Parameters Using a Focused Laser Source and Heavy Ion Cyclotron on Example of a Library of Analog IP Units

dc.contributor.authorBorisov, A. Y.
dc.contributor.authorNovikov, A. A.
dc.contributor.authorPetrun, N. L.
dc.contributor.authorNefedova, A. A.
dc.contributor.authorChukov, G. V.
dc.contributor.authorПетрунь, Наталья Леонидовна
dc.contributor.authorЧуков, Георгий Викторович
dc.date.accessioned2024-11-29T16:28:29Z
dc.date.available2024-11-29T16:28:29Z
dc.date.issued2021
dc.description.abstract© 2021 IEEE.The sensitivity parameters based on the single event effects (SEE) for a library consisting of 51 analog and analog-to-digital IP units manufactured using CMOS/SOI technology with design standards of 180 nm were evaluated. The use of a pulsed picosecond focused laser facility "PICO-4"in determining the sensitivity parameters made it possible to minimize the use of a heavy ion cyclotron. When a focused laser source and a heavy ion cyclotron are used together, the location of the most sensitive areas on the crystal is determined, which is impossible when using only a cyclotron, while the error in determining the threshold linear energy transfer for the occurrence of SEE is reduced. Using a focused laser source, sensitive regions of IP units with threshold values of linear energy losses that are unattainable when conducting an experiment on a heavy ion cyclotron are determined.
dc.identifier.citationThe Optimal Estimation of Single Event Effects Sensitivity Parameters Using a Focused Laser Source and Heavy Ion Cyclotron on Example of a Library of Analog IP Units / Borisov, A.Y. [et al.] // SIBCON 2021 - International Siberian Conference on Control and Communications. - 2021. - 10.1109/SIBCON50419.2021.9438936
dc.identifier.doi10.1109/SIBCON50419.2021.9438936
dc.identifier.urihttps://www.doi.org/10.1109/SIBCON50419.2021.9438936
dc.identifier.urihttps://www.scopus.com/record/display.uri?eid=2-s2.0-85107632944&origin=resultslist
dc.identifier.urihttp://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=Alerting&SrcApp=Alerting&DestApp=WOS_CPL&DestLinkType=FullRecord&UT=WOS:000680842100083
dc.identifier.urihttps://openrepository.mephi.ru/handle/123456789/24211
dc.relation.ispartofSIBCON 2021 - International Siberian Conference on Control and Communications
dc.titleThe Optimal Estimation of Single Event Effects Sensitivity Parameters Using a Focused Laser Source and Heavy Ion Cyclotron on Example of a Library of Analog IP Units
dc.typeConference Paper
dspace.entity.typePublication
relation.isAuthorOfPublicationa208e8e8-c292-4dcc-afe6-935557ad3327
relation.isAuthorOfPublicationd724e4cb-714a-4e50-a262-ce949f36fd58
relation.isAuthorOfPublication.latestForDiscoverya208e8e8-c292-4dcc-afe6-935557ad3327
relation.isOrgUnitOfPublication06e1796d-4f55-4057-8d7e-bb2f3b5676f5
relation.isOrgUnitOfPublication543ffddb-d115-4466-be75-83b0f2c5a473
relation.isOrgUnitOfPublication.latestForDiscovery06e1796d-4f55-4057-8d7e-bb2f3b5676f5
Файлы
Коллекции