Publication: The Optimal Estimation of Single Event Effects Sensitivity Parameters Using a Focused Laser Source and Heavy Ion Cyclotron on Example of a Library of Analog IP Units
| dc.contributor.author | Borisov, A. Y. | |
| dc.contributor.author | Novikov, A. A. | |
| dc.contributor.author | Petrun, N. L. | |
| dc.contributor.author | Nefedova, A. A. | |
| dc.contributor.author | Chukov, G. V. | |
| dc.contributor.author | Петрунь, Наталья Леонидовна | |
| dc.contributor.author | Чуков, Георгий Викторович | |
| dc.date.accessioned | 2024-11-29T16:28:29Z | |
| dc.date.available | 2024-11-29T16:28:29Z | |
| dc.date.issued | 2021 | |
| dc.description.abstract | © 2021 IEEE.The sensitivity parameters based on the single event effects (SEE) for a library consisting of 51 analog and analog-to-digital IP units manufactured using CMOS/SOI technology with design standards of 180 nm were evaluated. The use of a pulsed picosecond focused laser facility "PICO-4"in determining the sensitivity parameters made it possible to minimize the use of a heavy ion cyclotron. When a focused laser source and a heavy ion cyclotron are used together, the location of the most sensitive areas on the crystal is determined, which is impossible when using only a cyclotron, while the error in determining the threshold linear energy transfer for the occurrence of SEE is reduced. Using a focused laser source, sensitive regions of IP units with threshold values of linear energy losses that are unattainable when conducting an experiment on a heavy ion cyclotron are determined. | |
| dc.identifier.citation | The Optimal Estimation of Single Event Effects Sensitivity Parameters Using a Focused Laser Source and Heavy Ion Cyclotron on Example of a Library of Analog IP Units / Borisov, A.Y. [et al.] // SIBCON 2021 - International Siberian Conference on Control and Communications. - 2021. - 10.1109/SIBCON50419.2021.9438936 | |
| dc.identifier.doi | 10.1109/SIBCON50419.2021.9438936 | |
| dc.identifier.uri | https://www.doi.org/10.1109/SIBCON50419.2021.9438936 | |
| dc.identifier.uri | https://www.scopus.com/record/display.uri?eid=2-s2.0-85107632944&origin=resultslist | |
| dc.identifier.uri | http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=Alerting&SrcApp=Alerting&DestApp=WOS_CPL&DestLinkType=FullRecord&UT=WOS:000680842100083 | |
| dc.identifier.uri | https://openrepository.mephi.ru/handle/123456789/24211 | |
| dc.relation.ispartof | SIBCON 2021 - International Siberian Conference on Control and Communications | |
| dc.title | The Optimal Estimation of Single Event Effects Sensitivity Parameters Using a Focused Laser Source and Heavy Ion Cyclotron on Example of a Library of Analog IP Units | |
| dc.type | Conference Paper | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | a208e8e8-c292-4dcc-afe6-935557ad3327 | |
| relation.isAuthorOfPublication | d724e4cb-714a-4e50-a262-ce949f36fd58 | |
| relation.isAuthorOfPublication.latestForDiscovery | a208e8e8-c292-4dcc-afe6-935557ad3327 | |
| relation.isOrgUnitOfPublication | 06e1796d-4f55-4057-8d7e-bb2f3b5676f5 | |
| relation.isOrgUnitOfPublication | 543ffddb-d115-4466-be75-83b0f2c5a473 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | 06e1796d-4f55-4057-8d7e-bb2f3b5676f5 |