dc.description.abstract© 2020 Obninsk Institute for Nuclear Power Engineering, National Research Nuclear University 'MEPhI'. All rights reserved.The paper presents the results of experimental determination of the induced activity in copper"/aluminum"based activation detectors when irradiated with neutrons with energy of about 14 MeV. The activation detectors were square"shaped metal plates with a thickness from 1.0 to 1.5 mm and a side size about 5.0 cm. Such samples require a specific method for measuring the induced activity, which will take into account large sizes of the plate relate to the size of gamma"detector or neutron source. The detectors described in this work can be used to study low"intensity neutron fluxes (with a flux density of up to 106n/cm2·s). It is shown that, when working with such detectors, the usual methods for calculating the induced activity in thin activation detectors are applicable, with corrections that take into account the emerging features of the "neutron source - activation detector" and "activation detector - secondary radiation detector" geometries. The effects of absorption of primary and secondary radiation by the detector substance are also revealed. The Geant4 tools were used to calculate the geometric factors and theoretical induced activity value. The study confirms the applicability of such activation detectors for solving the problem of determining the yield of neutrons with energy of about 14 MeV from a neutron generator target. The results of the experiments coincide, within the margin of error, with the results of simulations performed using the Geant4 tools.
dc.format.extentС. 156-167
dc.identifier.citationExperimental determination of the induced activity in activation detectors of a complex geometric shape / Ibragimov, R.F. [et al.] // Izvestiya Wysshikh Uchebnykh Zawedeniy, Yadernaya Energetika. - 2020. - 2. - P. 156-167. - 10.26583/NPE.2020.2.14
dc.identifier.doi10.26583/NPE.2020.2.14
dc.identifier.urihttps://www.doi.org/10.26583/NPE.2020.2.14
dc.identifier.urihttps://www.scopus.com/record/display.uri?eid=2-s2.0-85091361000&origin=resultslist
dc.identifier.urihttps://openrepository.mephi.ru/handle/123456789/22379
dc.relation.ispartofIzvestiya Wysshikh Uchebnykh Zawedeniy, Yadernaya Energetika
dc.titleExperimental determination of the induced activity in activation detectors of a complex geometric shape
dc.typeArticle
dspace.entity.typePublication
oaire.citation.volume2
relation.isAuthorOfPublication39697d3b-0bc6-4611-a47d-672f15868102
relation.isAuthorOfPublication56b5aa2d-49b5-4707-ac9e-2109527dd93d
relation.isAuthorOfPublication464ab598-7910-4155-9edc-d364e9f6b102
relation.isAuthorOfPublicationc7978fdf-e70e-4fcb-ae5a-2361829e3363
relation.isAuthorOfPublication.latestForDiscovery39697d3b-0bc6-4611-a47d-672f15868102
relation.isOrgUnitOfPublication74cb61de-96b0-45f9-956d-515149fba360
relation.isOrgUnitOfPublicationba0b4738-e6bd-4285-bda5-16ab2240dbd1
relation.isOrgUnitOfPublication.latestForDiscovery74cb61de-96b0-45f9-956d-515149fba360
Файлы
Коллекции