Publication:
Performance of the Conventional Divertor in TRT

dc.contributor.authorKukushkin, A. S.
dc.contributor.authorPshenov, A. A.
dc.date.accessioned2024-11-30T00:36:32Z
dc.date.available2024-11-30T00:36:32Z
dc.date.issued2021
dc.description.abstract© 2021, Pleiades Publishing, Ltd.Abstract: The paper presents the first results of SOLPS4.3 modeling of the TRT divertor within the conventional paradigm: a single-null poloidal divertor with solid metal plasma-facing surfaces. It is shown that at the full plasma current of ~5 MA and heating power of 25–40 MW, one should expect no wide operational window in the parameter space, which would ensure the possibility of a comfortable, soft control of the operation of the whole machine. The key problems are the heat load of the divertor plates and compatibility with good confinement of the core plasma.
dc.format.extentС. 1238-1244
dc.identifier.citationKukushkin, A. S. Performance of the Conventional Divertor in TRT / Kukushkin, A.S., Pshenov, A.A. // Plasma Physics Reports. - 2021. - 47. - № 12. - P. 1238-1244. - 10.1134/S1063780X21110209
dc.identifier.doi10.1134/S1063780X21110209
dc.identifier.urihttps://www.doi.org/10.1134/S1063780X21110209
dc.identifier.urihttps://www.scopus.com/record/display.uri?eid=2-s2.0-85121310388&origin=resultslist
dc.identifier.urihttp://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=Alerting&SrcApp=Alerting&DestApp=WOS_CPL&DestLinkType=FullRecord&UT=WOS:000730216400005
dc.identifier.urihttps://openrepository.mephi.ru/handle/123456789/25108
dc.relation.ispartofPlasma Physics Reports
dc.titlePerformance of the Conventional Divertor in TRT
dc.typeArticle
dspace.entity.typePublication
oaire.citation.issue12
oaire.citation.volume47
relation.isOrgUnitOfPublicationdcdb137c-0528-46a5-841b-780227a67cce
relation.isOrgUnitOfPublication.latestForDiscoverydcdb137c-0528-46a5-841b-780227a67cce
Файлы
Коллекции