Publication:
Preconcentration of vapors of low-volatile explosives for ion mobility spectrometry

dc.contributor.authorAkmalov, A. E.
dc.contributor.authorChistyakov, A. A.
dc.contributor.authorKotkovskii, G. E.
dc.contributor.authorKostarev, V. A.
dc.contributor.authorLavrinenko, K. N.
dc.contributor.authorАкмалов, Артём Эдуардович
dc.contributor.authorЧистяков, Александр Александрович
dc.contributor.authorКотковский, Геннадий Евгеньевич
dc.contributor.authorКостарев, Виталий Алексеевич
dc.contributor.authorЛавриненко, Кирилл Николаевич
dc.date.accessioned2024-11-29T23:04:35Z
dc.date.available2024-11-29T23:04:35Z
dc.date.issued2021
dc.description.abstract© 2021 SPIEThe issue of civil security and prevention of terrorist attacks in public places is becoming more and more actual every year. In this regard, increased attention is paid to detection of explosives. Of particular interest are methods to detect trinitrotoluene (TNT), hexogen (RDX), penthrite (PETN), octogen (HMX). Recently, gas-analytical, nuclear-physical, electromagnetic, terahertz, and biological detection methods have been developed. The lowest detection limit was achieved using gas-analytical methods, namely the non-linear ion mobility spectrometry method, with a limit of detection of 5.10-15 g/cm3. However, the question of feasibility of using these methods in real conditions is increasingly raised. There is an opinion that it is much more effective to detect explosives by traces than by vapor. In this work we investigated the possibility of detecting vapors of pure explosives with low saturated pressure of vapors. By the example of pure and faсtory hexogen, using the method of thermal-programmed desorption and mass spectrometry, it was shown that it is hexogen vapor, and not technological impurities or additives with saturated vapor pressure exceeding the saturated vapor pressure of hexogen, that are registered in the gas phase by ion mobility spectrometry. A technique was developed and proposed to concentrate RDX vapors. Using temperature-programmed desorption, the minimal time of concentration and surface fill factor were determined.
dc.identifier.citationPreconcentration of vapors of low-volatile explosives for ion mobility spectrometry / Akmalov, A.E. [et al.] // Proceedings of SPIE - The International Society for Optical Engineering. - 2021. - 11869. - 10.1117/12.2597962
dc.identifier.doi10.1117/12.2597962
dc.identifier.urihttps://www.doi.org/10.1117/12.2597962
dc.identifier.urihttps://www.scopus.com/record/display.uri?eid=2-s2.0-85118845235&origin=resultslist
dc.identifier.urihttps://openrepository.mephi.ru/handle/123456789/24958
dc.relation.ispartofProceedings of SPIE - The International Society for Optical Engineering
dc.titlePreconcentration of vapors of low-volatile explosives for ion mobility spectrometry
dc.typeConference Paper
dspace.entity.typePublication
oaire.citation.volume11869
relation.isAuthorOfPublicationdec281e4-1bc3-4915-a9d3-29c3921bc4c4
relation.isAuthorOfPublication2bcf3ea6-b96d-4ef0-8d9a-f78f774cec84
relation.isAuthorOfPublication650702d9-1bf6-4c3c-b1c7-feca4e50fea2
relation.isAuthorOfPublication22a42c23-85c0-44a6-b596-d4d95f4b249f
relation.isAuthorOfPublication6fbe22d4-1839-437a-b4da-2dcd4c9a48bc
relation.isAuthorOfPublication.latestForDiscoverydec281e4-1bc3-4915-a9d3-29c3921bc4c4
relation.isOrgUnitOfPublication06e1796d-4f55-4057-8d7e-bb2f3b5676f5
relation.isOrgUnitOfPublication543ffddb-d115-4466-be75-83b0f2c5a473
relation.isOrgUnitOfPublication.latestForDiscovery06e1796d-4f55-4057-8d7e-bb2f3b5676f5
Файлы
Коллекции