Publication: Using Laser-Induced Breakdown Spectroscopy and Mass Spectrometry to Determine the Retention of Deuterium in Titanium Films
| dc.contributor.author | Efimov, N. E. | |
| dc.contributor.author | Sinelnikov, D. N. | |
| dc.contributor.author | Sinelnikov,D.N. | |
| dc.contributor.author | Bulgadaryan, D. G. | |
| dc.contributor.author | Gasparyan, Y. M. | |
| dc.contributor.author | Gasparyan,Y.M. | |
| dc.contributor.author | Ефимов, Никита Евгеньевич | |
| dc.contributor.author | Синельников, Дмитрий Николаевич | |
| dc.contributor.author | Гаспарян, Юрий Микаэлович | |
| dc.contributor.author | Вовченко, Евгений Дмитриевич | |
| dc.contributor.author | Крат, Степан Андреевич | |
| dc.date.accessioned | 2024-12-25T14:12:48Z | |
| dc.date.available | 2024-12-25T14:12:48Z | |
| dc.date.issued | 2022 | |
| dc.description.abstract | © 2022, Allerton Press, Inc.Abstract: The sensitivities of laser-induced breakdown spectroscopy and quadrupole mass spectrometry are compared to determine the deuterium retained in titanium films using a nanosecond Nd:YAG laser. Simultaneous measurements are made in the 1–18 J cm−2 range of energy densities. Considerably higher sensitivity of mass spectrometry is revealed, along with the possibility of non-destructive analysis at low energy densities. | |
| dc.format.extent | С. 532-535 | |
| dc.identifier.citation | Using Laser-Induced Breakdown Spectroscopy and Mass Spectrometry to Determine the Retention of Deuterium in Titanium Films / Efimov, N.E. [et al.] // Bulletin of the Russian Academy of Sciences: Physics. - 2022. - 86. - № 5. - P. 532-535. - 10.3103/S1062873822050057 | |
| dc.identifier.doi | 10.3103/S1062873822050057 | |
| dc.identifier.uri | https://www.doi.org/10.3103/S1062873822050057 | |
| dc.identifier.uri | https://www.scopus.com/record/display.uri?eid=2-s2.0-85131443262&origin=resultslist | |
| dc.identifier.uri | https://openrepository.mephi.ru/handle/123456789/27959 | |
| dc.relation.ispartof | Bulletin of the Russian Academy of Sciences: Physics | |
| dc.title | Using Laser-Induced Breakdown Spectroscopy and Mass Spectrometry to Determine the Retention of Deuterium in Titanium Films | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| oaire.citation.issue | 5 | |
| oaire.citation.volume | 86 | |
| relation.isAuthorOfPublication | 80fa45c4-6d72-4001-98eb-50dcc5ab3a07 | |
| relation.isAuthorOfPublication | 4f6f2fcb-29aa-4f64-a710-49ec3d0da924 | |
| relation.isAuthorOfPublication | 7c09c13b-5454-4e2d-960e-7785484ee06a | |
| relation.isAuthorOfPublication | f6cb4735-ae00-4512-b5ee-6e6802668960 | |
| relation.isAuthorOfPublication | 91628677-e66c-4d8d-8358-5fef82aacaf7 | |
| relation.isAuthorOfPublication.latestForDiscovery | 80fa45c4-6d72-4001-98eb-50dcc5ab3a07 | |
| relation.isOrgUnitOfPublication | dcdb137c-0528-46a5-841b-780227a67cce | |
| relation.isOrgUnitOfPublication.latestForDiscovery | dcdb137c-0528-46a5-841b-780227a67cce |