Publication: Anisotropic flow measurements with multi-purpose detector at NICA
dc.contributor.author | Taranenko, A. | |
dc.contributor.author | Parfenov, P. | |
dc.contributor.author | Idrisov, D. | |
dc.contributor.author | Luong, V. B. | |
dc.contributor.author | Demanov, A. | |
dc.contributor.author | Truttse, A. | |
dc.contributor.author | Volodikhin, E. | |
dc.contributor.author | Тараненко, Аркадий Владимирович | |
dc.contributor.author | Парфенов, Петр Евгеньевич | |
dc.contributor.author | Идрисов, Дим Маратович | |
dc.contributor.author | Деманов, Александр Евгеньевич | |
dc.contributor.author | Трутце, Антон Андреевич | |
dc.contributor.author | Володихин, Евгений Андреевич | |
dc.date.accessioned | 2024-11-29T17:43:41Z | |
dc.date.available | 2024-11-29T17:43:41Z | |
dc.date.issued | 2021 | |
dc.description.abstract | © 2021 Jagellonian University. All rights reserved.The anisotropic transverse flow is one of the key observables to study the properties of dense matter created in heavy-ion collisions. The performance of Multi-Purpose Detector for directed and elliptic flow measurements is studied with Monte Carlo simulations of heavy-ion collisions at NICA energies √sNN = 4–11 GeV. | |
dc.format.extent | С. 515-518 | |
dc.identifier.citation | Anisotropic flow measurements with multi-purpose detector at NICA / Taranenko, A. [et al.] // Acta Physica Polonica B, Proceedings Supplement. - 2021. - 14. - № 3. - P. 515-518. - 10.5506/APHYSPOLBSUPP.14.515 | |
dc.identifier.doi | 10.5506/APHYSPOLBSUPP.14.515 | |
dc.identifier.uri | https://www.doi.org/10.5506/APHYSPOLBSUPP.14.515 | |
dc.identifier.uri | https://www.scopus.com/record/display.uri?eid=2-s2.0-85110361364&origin=resultslist | |
dc.identifier.uri | http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=Alerting&SrcApp=Alerting&DestApp=WOS_CPL&DestLinkType=FullRecord&UT=WOS:000742772400007 | |
dc.identifier.uri | https://openrepository.mephi.ru/handle/123456789/24380 | |
dc.relation.ispartof | Acta Physica Polonica B, Proceedings Supplement | |
dc.title | Anisotropic flow measurements with multi-purpose detector at NICA | |
dc.type | Conference Paper | |
dspace.entity.type | Publication | |
oaire.citation.issue | 3 | |
oaire.citation.volume | 14 | |
relation.isAuthorOfPublication | 0251bcb9-399a-497b-a1f2-77360ac345a6 | |
relation.isAuthorOfPublication | 303832ec-af65-4842-a1d6-beb69ecaea63 | |
relation.isAuthorOfPublication | 7c380af4-9f40-4030-9c40-07011dee3632 | |
relation.isAuthorOfPublication | 869f3671-a1f5-4def-9670-ac153c0bec44 | |
relation.isAuthorOfPublication | 711ed0f1-4b54-43d2-b280-82ae884c8a69 | |
relation.isAuthorOfPublication | c4b9770b-128e-49d9-b0f0-6451c6a6d0d3 | |
relation.isAuthorOfPublication.latestForDiscovery | 0251bcb9-399a-497b-a1f2-77360ac345a6 | |
relation.isOrgUnitOfPublication | ba0b4738-e6bd-4285-bda5-16ab2240dbd1 | |
relation.isOrgUnitOfPublication | 06e1796d-4f55-4057-8d7e-bb2f3b5676f5 | |
relation.isOrgUnitOfPublication | 543ffddb-d115-4466-be75-83b0f2c5a473 | |
relation.isOrgUnitOfPublication.latestForDiscovery | ba0b4738-e6bd-4285-bda5-16ab2240dbd1 |