Publication: Effect of temporal pulse shape on urinary stone phantom retropulsion rate and ablation efficiency using holmium:YAG and super-pulse thulium fibre lasers
Дата
2020
Авторы
Ventimiglia, E.
Doizi, S.
Traxer, O.
Kovalenko, A.
Andreeva, V.
Journal Title
Journal ISSN
Volume Title
Издатель
Аннотация
© 2020 The Authors BJU International © 2020 BJU International Published by John Wiley & Sons LtdObjective: To investigate the effects of laser temporal pulse shaping of the super-pulse thulium fibre laser (SPTFL) and to compare these in controlled in vitro conditions with various holmium: yttrium aluminium garnet (Ho:YAG) pulse delivery modes. Materials and Methods: The SPTFL (Urolase SP, IRE-Polus, Fryazino, Russia), with an emission wavelength of 1.94 μm, and a Ho:YAG laser (P120H; Lumenis, Yokneam, Israel) with Moses technology were compared. Pulse shape, stone retropulsion and ablation efficiency were evaluated using BegoStones and compared for each laser mode: short (SP), long (LP), and Moses pulse (MP) for Ho:YAG, regular pulse (RP) and dual pulse (DP) for SPTFL. Results: The Ho:YAG SP mode exhibited an asymmetrical pulse shape, with a steep leading slope and a much more gradual trailing slope, without any flat section. Pulses generated by the SPTFL were significantly longer and therefore had lower peak power than those generated by the Ho:YAG laser at equivalent energy settings. Retropulsion for the holmium:YAG LP and MP modes was similar and lower than that for the SP mode, but higher than for the SPTFL (all P ≤ 0.02), with an average stone displacement approximately four times and two times lower for SPTFL as compared to the Ho:YAG laser. Comparison of ablation volumes indicated that the SPTFL induced significantly higher (twofold) ablation than the Ho:YAG laser. Conclusions: The magnitude and initial velocity of stone retropulsion decreased with longer pulse duration and lower pulse peak power, without sacrificing ablation efficiency. These observations are manifest when comparing the Ho:YAG laser with the SPTFL. The novel SPTFL provides greater versatility and control of pulse variables than the Ho:YAG laser. Further clinical investigation of practical benefits achievable with pulse-shaping SPTFL modes is warranted.
Описание
Ключевые слова
Цитирование
Effect of temporal pulse shape on urinary stone phantom retropulsion rate and ablation efficiency using holmium:YAG and super-pulse thulium fibre lasers / Ventimiglia, E. [et al.] // BJU International. - 2020. - 10.1111/bju.15079
URI
https://www.doi.org/10.1111/bju.15079
https://www.scopus.com/record/display.uri?eid=2-s2.0-85084806725&origin=resultslist
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=Alerting&SrcApp=Alerting&DestApp=WOS_CPL&DestLinkType=FullRecord&UT=WOS:000533408700001
https://openrepository.mephi.ru/handle/123456789/21828
https://www.scopus.com/record/display.uri?eid=2-s2.0-85084806725&origin=resultslist
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=Alerting&SrcApp=Alerting&DestApp=WOS_CPL&DestLinkType=FullRecord&UT=WOS:000533408700001
https://openrepository.mephi.ru/handle/123456789/21828