Publication:
Effect of temporal pulse shape on urinary stone phantom retropulsion rate and ablation efficiency using holmium:YAG and super-pulse thulium fibre lasers

Дата
2020
Авторы
Ventimiglia, E.
Doizi, S.
Traxer, O.
Kovalenko, A.
Andreeva, V.
Journal Title
Journal ISSN
Volume Title
Издатель
Научные группы
Организационные подразделения
Выпуск журнала
Аннотация
© 2020 The Authors BJU International © 2020 BJU International Published by John Wiley & Sons LtdObjective: To investigate the effects of laser temporal pulse shaping of the super-pulse thulium fibre laser (SPTFL) and to compare these in controlled in vitro conditions with various holmium: yttrium aluminium garnet (Ho:YAG) pulse delivery modes. Materials and Methods: The SPTFL (Urolase SP, IRE-Polus, Fryazino, Russia), with an emission wavelength of 1.94 μm, and a Ho:YAG laser (P120H; Lumenis, Yokneam, Israel) with Moses technology were compared. Pulse shape, stone retropulsion and ablation efficiency were evaluated using BegoStones and compared for each laser mode: short (SP), long (LP), and Moses pulse (MP) for Ho:YAG, regular pulse (RP) and dual pulse (DP) for SPTFL. Results: The Ho:YAG SP mode exhibited an asymmetrical pulse shape, with a steep leading slope and a much more gradual trailing slope, without any flat section. Pulses generated by the SPTFL were significantly longer and therefore had lower peak power than those generated by the Ho:YAG laser at equivalent energy settings. Retropulsion for the holmium:YAG LP and MP modes was similar and lower than that for the SP mode, but higher than for the SPTFL (all P ≤ 0.02), with an average stone displacement approximately four times and two times lower for SPTFL as compared to the Ho:YAG laser. Comparison of ablation volumes indicated that the SPTFL induced significantly higher (twofold) ablation than the Ho:YAG laser. Conclusions: The magnitude and initial velocity of stone retropulsion decreased with longer pulse duration and lower pulse peak power, without sacrificing ablation efficiency. These observations are manifest when comparing the Ho:YAG laser with the SPTFL. The novel SPTFL provides greater versatility and control of pulse variables than the Ho:YAG laser. Further clinical investigation of practical benefits achievable with pulse-shaping SPTFL modes is warranted.
Описание
Ключевые слова
Цитирование
Effect of temporal pulse shape on urinary stone phantom retropulsion rate and ablation efficiency using holmium:YAG and super-pulse thulium fibre lasers / Ventimiglia, E. [et al.] // BJU International. - 2020. - 10.1111/bju.15079
Коллекции