Publication:
Magnetometry based method for investigation of nanoparticle clearance from circulation in a liver perfusion model

Дата
2019
Авторы
Zelepukin, I. V.
Yaremenko, A. V.
Petersen, E. V.
Deyev, S. M.
Nikitin, P. I.
Journal Title
Journal ISSN
Volume Title
Издатель
Научные группы
Организационные подразделения
Организационная единица
Инженерно-физический институт биомедицины
Цель ИФИБ и стратегия развития – это подготовка высококвалифицированных кадров на базе передовых исследований и разработок новых перспективных методов и материалов в области инженерно-физической биомедицины. Занятие лидерских позиций в биомедицинских технологиях XXI века и внедрение их в образовательный процесс, что отвечает решению практикоориентированной задачи мирового уровня – диагностике и терапии на клеточном уровне социально-значимых заболеваний человека.
Выпуск журнала
Аннотация
Nanoparticles (NPs) are among the most promising agents for advanced theranostics. However, their functioning in vivo is severely inhibited by the mononuclear phagocyte system (MPS), which rapidly removes all foreign entities from blood circulation. Little is known about the sequestration mechanisms and the ways to counteract them. New methods are highly demanded for investigation with high scrutiny of each aspect of NP clearance from blood. For example, while liver macrophages capture the majority of the administered particles, reliable investigation of this process in absence of other MPS components is hard to implement in vivo. Here, we demonstrate a novel method for real-time investigation hepatic uptake of NPs in an isolated perfused liver based on an extremely accurate magnetometric registration technique. The signal is obtained solely from the magnetic NPs without any 'background' from blood or tissues, which is a significant advantage over other techniques, e.g. optical ones. We illustrate the method capacity by investigation of behavior of different particles and show good correlation with in vivo studies. We also demonstrate notable suitability of the method for studying the NP clearance from the flow in the user-defined mediums, e.g. those containing specific serum components. Finally, the method was applied to reveal an interesting effect of short-term decrease of liver macrophage activity after the first interaction with small amounts of NPs. The developed perfusion model based on the high-performance magnetometry can be used for finding new mechanisms of NP sequestration and for development of novel 'stealth' nanoagents.
Описание
Ключевые слова
Цитирование
Magnetometry based method for investigation of nanoparticle clearance from circulation in a liver perfusion model / Zelepukin, I.V. [et al.] // Nanotechnology. - 2019. - 30. - № 10. - 10.1088/1361-6528/aafa3a
Коллекции