Персона: Казиев, Андрей Викторович
Email Address
Birth Date
Научные группы
Организационные подразделения
Статус
Фамилия
Имя
Имя
Результаты поиска
Diagnostics of ion fluxes in low-temperature laboratory and industrial plasmas
2019, Kolodko, D, V., Ageychenkov, D. G., Kaziev, A, V., Leonova, K. A., Kharkov, M. M., Tumarkin, A. V., Колодко, Добрыня Вячеславич, Агейченков, Дмитрий Григорьевич, Казиев, Андрей Викторович, Харьков, Максим Михайлович, Тумаркин, Александр Владимирович
We studied the ion fluxes on metal surfaces in the inductively coupled plasma reactor as a test facility. The gas mixture of argon and nitrogen was used, with 0.44 Pa total pressure. The radiofrequency power was varied in a wide range (250-2000 W). The ion fluxes were sampled in situ using a specially designed electrostatic extractor and then analyzed with a custom-built magnetic sector mass-separator. The gas composition was independently monitored by the quadrupole analyzer. All measurements were accompanied by optical emission spectroscopy (OES). The correlations of measured optical and corpuscular data are discussed. The conversion function linking optical and corpuscular intensities for Ar/N-2 radiofrequency discharge was determined.
Direct ion content measurements in a non-sputtering magnetron discharge
2019, Kaziev, A. V., Kolodko, D. V., Ageychenkov, D. G., Tumarkin, A. V., Kharkov, M. M., Stepanova, T. V., Казиев, Андрей Викторович, Колодко, Добрыня Вячеславич, Агейченков, Дмитрий Григорьевич, Тумаркин, Александр Владимирович, Харьков, Максим Михайлович, Степанова, Татьяна Владимировна
In present contribution we report the first direct measurements of ion fluxes in a nonsputtering magnetron discharge (NSMD) with Al cathode in Ar/O-2 mixtures. The diagnostic unit comprising three-electrode electrostatic lens ion extractor, magnetic sector mass-analyzer, and a vacuum electron multiplier was calibrated and then used to record the time-resolved ion counts of Al+ and Ar+ both in NSMD and arc regimes. The results clearly indicate that in NSMD the dominant species are Ar ions while Al ion signal is lower than the sensitivity limit due to noise level, in contrast to the arc discharge. The capabilities of the diagnostics setup and its sensitivity limits are discussed.
Langmuir probe diagnostics of an impulse magnetron discharge with hot Cr target
2019, Tumarkin, A. V., Kaziev, A, V., Leonova, K. A., Kharkov, M. M., Kolodko, D. V., Khomyakov, A. Yu., Тумаркин, Александр Владимирович, Казиев, Андрей Викторович, Харьков, Максим Михайлович, Колодко, Добрыня Вячеславич
Impulse magnetron discharge (pulse duration 20 ms) with uncooled Cr target has been investigated with a specially designed Langmuir probe setup in a wide range of parameters (magnetic field and discharge power). The spatial distributions of electron temperature and plasma density have been measured in the gasless self-sputtering mode. It has been shown that in the gasless high-power pulsed discharge with hot Cr target, plasma density is as high as 5 x 10(18) M-3 at a pulsed power density of 1430 W/cm(2), while the electron temperature drops to values below 1 eV.